A cushion block rarely fails by being crushed. It fails by moving. After a long vibration run a wedged block can work towards a corner, leaving the component bearing on the crate wall while the pack still looks intact outside. We specify each EPE block as a positioned part with a location, a preload, and a check, not as loose stuffing. The pack is judged from the inside, not by an unmarked outer carton.
Placement starts with the part drawing, not the box's empty space. Weight and centre of gravity set the load bearing points; finished faces set the no touch zones. Blocks are set only on agreed support faces, with deliberate clearance elsewhere so the part can move a controlled distance rather than being jammed against every wall. That clearance is stated on the drawing.
Holding the blocks needs its own design. Moulded ledges, slots, a layer pad bearing down, and interlocking block profiles give positive location. A sleeve or light tack adhesive covers boxes without ledges. Friction alone is not accepted; smooth EPE on smooth PP loses grip once dust or oil appears. Every block has a home that can be seen during packing. Assembly order is printed on the packing sheet so blocks go in before the part.
A small preload takes up clearance and holds the part still; too much makes EPE creep. Interference is set against a measured compression value, then rechecked after a loaded dwell and after washing. Density and thickness come from part weight and drop risk, and both are stated on the drawing, not left to the packer.
Verification watches position as closely as damage. Sample packs run vibration, drop, and stacked load sequences; on opening we check that each block is still on its ledge and no part has touched the wall. A printed witness line makes migration obvious at a glance and gives the store a clear pass or fail rule.
Discrete blocks suit a changing part list. Service parts and low volume programmes take a new block layout without a new tool, with no tooling charge, and a worn block is replaced alone. Where one part runs steadily in high volume, a moulded insert gives more consistent positioning; the choice is a volume decision.
To lay out a set of blocks, send the part drawing with weight, centre of gravity, allowed and forbidden contact faces, the crate inner dimensions, vibration and drop requirements, cleaning agents, temperature range, and how many variants must share the same box. We return a block position drawing with a stated density and preload for each location, sample packs, and the vibration and re fit records.