A tray that wobbles is not a cosmetic problem. Every kilometre of transport turns that small movement into a repeated impact at the same spot, and a part that arrives with a polished stripe or a chipped corner usually met its tray a few thousand times before it met anything else.
The common assumption is that a perfect fit means zero clearance. In reality it means the right clearance, calculated from three tolerances that always exist together: the manufacturing tolerance of the part itself, the forming tolerance of the tray, and the shrinkage that plastics undergo after they cool. Add them honestly and the cavity is sized with deliberate room, not guessed room.
Clearance is set differently at different faces. Datum surfaces that locate the part get tight values, often fractions of a millimetre, because their job is position. Non-critical walls get generous values, because their only job is to stay out of the way. Uniform tightness everywhere guarantees a tray that either grips loosely somewhere important or binds somewhere that does not matter.
Draft angle is part of the fit. Cavities formed without enough taper grip the part on extraction, and operators respond by levering the part out with a screwdriver, which is how trays die and parts get marked. Adequate draft on the release direction is what makes a tight fit acceptable to the person using it eight hours a day.
Shrinkage is measured rather than assumed. Formed sheet pulls toward the flutes as it cools, and moulded foam grades shrink by a known percentage while they age in the first days after production. We compensate the tool for both, so the tray that leaves the factory a week later still matches the tray that was approved as a sample.
Control effort goes where movement is possible. Rather than wrapping the whole part in a tight cavity, we add locating ribs at the two or three faces that can actually move, and leave the rest of the cavity open. A rib at a load-bearing face stops rotation; an open wall nearby adds nothing but cost.
Vibration testing is where the claim is verified. An approved tray set is loaded with real parts and run through a swept-frequency sequence matching road transport, then the displacement at each face is measured. A cavity that passed a static check but lets the part travel visibly under vibration fails here, in our plant rather than in yours.
First-article inspection is dimensional. Critical cavity dimensions are measured against the drawing and recorded, so later batches are compared to numbers rather than to memory, and a drift toward tighter fit is caught before parts stop dropping in.
When the part changes mid-year, the tolerance stack is redone rather than adjusted by eye. A small geometry change often leaves the cavity valid; the calculation is what confirms it, and the confirmation is recorded against the tray revision.
Give the part drawing with its tolerance table and the transport profile, and the cavity layout you get back states the clearance at each face and the test used to verify it.